Template:Scope of fluorescence application: Difference between revisions

From Bioblast
mNo edit summary
mNo edit summary
Line 1: Line 1:
:::: The scope of applications is defined by the excitation wavelengths of the Fluorescence-Sensor Green and Fluorescence-Sensor Blue and the selection of emission filters.
:::: The scope of applications is defined by the excitation wavelengths of the Fluorescence-Sensor Green and Fluorescence-Sensor Blue and the selection of emission filters.


:::: The O2k-Fluo LED2-Module (O2k series D to G) and O2k-Fluo Smart-Module (O2k series H and higher) are designed for measurements performed on samples placed in a stirred and temperature-controlled chamber. Fluorometric protocols based on measurements in cuvettes of various fluorometers can be used with the O2k-Fluo Modules, and extended by simultaneous measurement of respiration and monitoring or regulation of oxygen concentration. The excitation and emission wavelengths of the fluorophore must be suitable for use with both fluorescence modules. For examples see [[MiPNet17.05 O2k-Fluorescence LED2-Module#LED-intensity and amplification|LED-intensity and amplification]].
:::: The O2k-Fluo LED2-Module (O2k series D to G) and O2k-Fluo Smart-Module (O2k series H and higher) are designed for measurements performed on samples placed in a stirred and temperature-controlled chamber. Fluorometric protocols based on measurements in cuvettes of various fluorometers can be used with the O2k-Fluo Modules, and extended by simultaneous measurement of respiration and monitoring or regulation of oxygen concentration. The excitation and emission wavelengths of the fluorophore must be suitable for the filters and sensors of the O2k Fluo-Modules.


:::: The fluorescence modules are not designed to fulfill the functions of fluorescence microscopes or flow cytometers.
:::: The fluorescence modules are not designed to fulfill the functions of fluorescence microscopes or flow cytometers.

Revision as of 16:37, 23 November 2021

The scope of applications is defined by the excitation wavelengths of the Fluorescence-Sensor Green and Fluorescence-Sensor Blue and the selection of emission filters.
The O2k-Fluo LED2-Module (O2k series D to G) and O2k-Fluo Smart-Module (O2k series H and higher) are designed for measurements performed on samples placed in a stirred and temperature-controlled chamber. Fluorometric protocols based on measurements in cuvettes of various fluorometers can be used with the O2k-Fluo Modules, and extended by simultaneous measurement of respiration and monitoring or regulation of oxygen concentration. The excitation and emission wavelengths of the fluorophore must be suitable for the filters and sensors of the O2k Fluo-Modules.
The fluorescence modules are not designed to fulfill the functions of fluorescence microscopes or flow cytometers.
Cookies help us deliver our services. By using our services, you agree to our use of cookies.