MiPNet06.03 POS-calibration-SOP: Difference between revisions

From Bioblast
No edit summary
No edit summary
Β 
(145 intermediate revisions by 18 users not shown)
Line 1: Line 1:
{{Template:OROBOROS support page name}}
{{Publication
{{Publication
|title=Gnaiger E. Oxygen calibration and solubility in experimental media. Mitochondr. Physiol. Network 06.03.
|title=[[Image:O2k-Manual.jpg|right|70px|link=O2k-Manual|O2k-Manual]]O2k Quality Control 1: Polarographic oxygen sensors and accuracy of calibration.
|info=[http://www.oroboros.at/index.php?oxygen-solubilityΒ  MiPNet06.03_O2-Calib-Solubility]
|info=[[File:PDF.jpg|100px|link=https://wiki.oroboros.at/images/7/77/MiPNet06.03_POS-Calibration-SOP.pdf |Bioblast pdf]]Β  Β» [http://www.bioblast.at/index.php/File:MiPNet06.03_POS-Calibration-SOP.pdf Versions]
|authors=Gnaiger E
|authors=Oroboros
|year=*
|year=2023-02-06
|journal=Mitochondr. Physiol. Network
|journal=Mitochondr Physiol Network
|abstract=[[High-resolution respirometry]] critically depends on accurate calibration of the [[polarographic oxygen sensor]]s which respond to [[partial oxygen pressure]].Β  Expressing the oxygen signal in terms of partial pressure has several advantages, but respiration is expressed in molar units related to biochemical stoichiometries. Conversion of oxygen partial pressure to [[oxygen concentration]] requires accurate information on oxygen solubilities in experimental incubation media. Absolute errors up to 10% are commonly found in the established literature. The [[oxygen solubility]] of mitochondrial respiration medium [[MiR06]] relative to pure water (oxygen solubility factor, ''F''<sub>M</sub>) is 0.92, accurately determined (for MiR05, i.e. MiR06 without catalase; [[MiPNet14.13]]) at 37 Β°C and 30 Β°C.Β  At air saturation at standard barometric pressure (100 kPa) and 37 Β°C, the partial oxygen pressure is 19.63 kPa, and the oxygen concentration is 190.7 Β΅M in MiR06.Β  A clean and ready-to-use Oxygraph chamber is a requirement for saving time and quickly calibrating the polarographic oxygen sensors.
|abstract=Gnaiger E (2023) O2k Quality Control 1: Polarographic oxygen sensors and accuracy of calibration. Mitochondr Physiol Network 06.03(21):1-10.
|mipnetlab=AT_Innsbruck_OROBOROS
{{MiPNet pdf page linking to MitoPedia}}
|articletype=Protocol; Manual, MiPNet-online Publication
|mipnetlab=AT_Innsbruck_Oroboros
}}
}}
{{Labeling
|instruments=Oxygraph-2k, Protocol, MiPNet-Publication
|additional=O2k-SOP
|articletype=Protocol; Manual, MiPNet-online Publication
}}
==Info==


MiPNet11.08 integrated into MiPNet06.03.
== Keywords ==
{{Template:Keywords: Oxygen signal}}


::::Β» [[Oxygen calibration - DatLab]]


==Contents==


1 O2k-Chamber: Cleaning and Storage
{{Labeling
Β 
|area=Respiration, Instruments;methods
1.1 Cleaning the Chamber
|instruments=Oxygraph-2k, O2k-Manual
Β 
|additional=DatLab, O2k-SOP, DL7, Oxygen solubility, DL8,
1.2 Storage in 70% Ethanol
MitoFit 2021 Dark respiration, MitoFit 2021 Photosynthesis, DL8, PLoSONE2022ace-sce, MitoFit2022QC, POS
Β 
}}
2 Short Two-Point Calibration
Β 
3 Equations for Oxygen Calibration
Β 
3.1 Oxygen Concentration and Recorded Signal
Β 
3.2 Oxygen Pressure and POS Current
Β 
3.3 Oxygen Concentration and Oxygen Pressure
Β 
3.4 Oxygen Signal and Background Oxygen Consumption
Β 
4 O2 Solubility and Concentration at Air Saturation
Β 
4.1 Oxygen Pressure and Concentration
Β 
4.2 Temperature Effect on Saturation O2 Conc.
Β 
4.3 Barometric Pressure Effect on Saturation O2 Conc.
Β 
4.4 The O2 Solubility Factor in Salt Solutions
Β 
Β 
__NOTOC__

Latest revision as of 14:27, 27 July 2023


                  


O2k-Open Support

MiPNet06.03 POS-calibration-SOP


Publications in the MiPMap
O2k-Manual
O2k Quality Control 1: Polarographic oxygen sensors and accuracy of calibration.

Β» Bioblast pdf  Β» Versions

Oroboros (2023-02-06) Mitochondr Physiol Network

Abstract: Gnaiger E (2023) O2k Quality Control 1: Polarographic oxygen sensors and accuracy of calibration. Mitochondr Physiol Network 06.03(21):1-10.

O2k-technical support and open innovation
Open the pdf document above.
Β» Current O2k-series: NextGen-O2k Series XB and O2k Series J
Β» Current software versions DatLab 8.0: MitoPedia: DatLab


β€’ O2k-Network Lab: AT_Innsbruck_Oroboros


Keywords


Questions.jpg


Click to expand or collaps


Β» Oxygen calibration - DatLab


Labels: MiParea: Respiration, Instruments;methods 





HRR: Oxygraph-2k, O2k-Manual 

DatLab, O2k-SOP, DL7, Oxygen solubility, DL8, MitoFit 2021 Dark respiration, MitoFit 2021 Photosynthesis, DL8, PLoSONE2022ace-sce, MitoFit2022QC, POS 

Cookies help us deliver our services. By using our services, you agree to our use of cookies.