MiPNet11.05 imt-pti-pce: Difference between revisions
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
{{Publication | {{Publication | ||
|title=Gnaiger E (2005) Isolated mitochondria or permeabilized tissues and cells. Mitochondr Physiol Network 11.05. | |title=Gnaiger E (2005) Isolated mitochondria or permeabilized tissues and cells. Mitochondr Physiol Network 11.05. | ||
|info= | |info=[[Media:MiPNet11.05 Mitos-PermeabilizedCells.pdf|'''Open Access.MiPNet11.05.pdf''']], [http://www.bioblast.at/index.php/File:MiPNet11.05_Mitos-PermeabilizedCells.pdf Versions] | ||
|authors=OROBOROS | |authors=OROBOROS | ||
|year=2005 | |year=2005 | ||
Line 13: | Line 13: | ||
|instruments=Protocol | |instruments=Protocol | ||
}} | }} | ||
==Further information == | |||
:>> [http://www.oroboros.at/?Mitochondria-Tissue www Tisues] | |||
* Version 5: 2011-12-03 | * Version 5: 2011-12-03 | ||
* Version 1: 2005 | * Version 1: 2005 |
Revision as of 16:32, 28 October 2013
Gnaiger E (2005) Isolated mitochondria or permeabilized tissues and cells. Mitochondr Physiol Network 11.05. |
ยป Open Access.MiPNet11.05.pdf, Versions
OROBOROS (2005) Mitochondr Physiol Network
Abstract: Summary: Whereas isolated mitochondria remain one of the gold-standards in studies of bioenergetics and mitochondrial physiology, permeabilized tissues and cells have become an alternative with several advantages. But some disadvantages have to be considered, too, for optimum experimental design and critical evaluation of results.
โข O2k-Network Lab: AT_Innsbruck_OROBOROS
Labels: MiParea: mt-Biogenesis;mt-density
Preparation: Permeabilized cells, Permeabilized tissue, Isolated Mitochondria"Isolated Mitochondria" is not in the list (Intact organism, Intact organ, Permeabilized cells, Permeabilized tissue, Homogenate, Isolated mitochondria, SMP, Chloroplasts, Enzyme, Oxidase;biochemical oxidation, ...) of allowed values for the "Preparation" property.
HRR: Protocol"Protocol" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property.
Further information
- >> www Tisues
- Version 5: 2011-12-03
- Version 1: 2005