MiPNet17.17 Amplex-Mouse-brain: Difference between revisions

From Bioblast
(Created page with " {{Publication |title=Harrison DK (2012) O2k-Spectrophotometry - A MitoCom Project. Mitochondr Physiol Network 17.16. |info=[http://www.oroboros.at/index.php?id=o2k-spectrophotom...")
ย 
No edit summary
Line 1: Line 1:
{{Publication
{{Publication
|title=Harrison DK (2012) O2k-Spectrophotometry - A MitoCom Project. Mitochondr Physiol Network 17.16.
|title=Fasching M (2012) O2k-Fluorometry - A MitoCom Project. Mitochondr Physiol Network 17.17.
|info=[http://www.oroboros.at/index.php?id=o2k-spectrophotometry MiPNet17.16]
|info=[http://www.oroboros.at/index.php?id=o2k-fluorescenceled2-module MiPNet17.17]
|authors=Harrison DK, Fasching M, Gnaiger E
|authors=Fasching M, Sumbalova Z, Gnaiger E
|year=2012
|year=2012
|journal=Mitochondr Physiol Network
|journal=Mitochondr Physiol Network
|abstract=The principal thrust of the technical development of the O2k high-resolution respirometer within the MitoCom project is towards the O2k-Fluorometer. However, simultaneously, a parallel project is working towards the integration of spectrophotometry into the O2k in order to measure the redox state of cytochromes โ€“ particularly cytochromes c and aa3, but also cytochrome b.
|abstract=High-resolution respirometry [1] is extended by MultiSensor techniques allowing the simultaneous measurement of oxygen consumption and one additional parameter (mitochondrial membrane potential, pH, Ca2+, or NO concentration [2, 3]). Fluorometric methods are available for a wide range of analytical parameters of major interest in mitochochondrial physiology: H2O2 production, mitochondrial membrane potential, intracellular pH, Ca2+, Mg2+ , and NADH levels.
|keywords=Oxygraph-2k, High-resolution respirometry, Spectrophotometry, MitoCom
Advantages of the simultaneous measurement of additional parameters in a single respirometric chamber:
# Quality control of preparations by respirometric performance.
# Objective exclusion criteria for protocol related problems, e.g. overtitration of uncouplers, side effects of TPP+ or fluorophores.
# Elimination of artifacts of normalization for a mitochondrial marker when combining two methods in a single chamber.
# Additional information is acquired for a limited amount of sample.
# Oxygen dependence of parameters can be studied.
Here we introduce the O2k-Fluorescence LED2-Module, describe one selected stage in its development, and show its application for the simultaneous measurement of respiration and H2O2 production of mouse brain mitochondria.
|keywords=Oxygraph-2k, High-resolution respirometry, Spectrofluorometry, MitoCom
|mipnetlab=AT_Innsbruck_OROBOROS
|mipnetlab=AT_Innsbruck_OROBOROS
|articletype=Workshop, MiPNet-online Publication
|articletype=Workshop, MiPNet-online Publication
}}
}}
{{Labeling
{{Labeling
|instruments=Oxygraph-2k, Spectrophotometry, MiPNet-Publication
|instruments=Oxygraph-2k, Spectrofluorimetry, MiPNet-Publication
|articletype=Workshop, MiPNet-online Publication
|articletype=Workshop, MiPNet-online Publication
}}
}}

Revision as of 16:44, 10 January 2013

Publications in the MiPMap
Has title::Fasching M (2012) O2k-Fluorometry - A MitoCom Project. Mitochondr Physiol Network 17.17.

ยป [[Has info::MiPNet17.17]]

Was written by::Fasching M, Was written by::Sumbalova Z, Was written by::Gnaiger E (Was published in year::2012) Was published in journal::Mitochondr Physiol Network

Abstract: [[has abstract::High-resolution respirometry [1] is extended by MultiSensor techniques allowing the simultaneous measurement of oxygen consumption and one additional parameter (mitochondrial membrane potential, pH, Ca2+, or NO concentration [2, 3]). Fluorometric methods are available for a wide range of analytical parameters of major interest in mitochochondrial physiology: H2O2 production, mitochondrial membrane potential, intracellular pH, Ca2+, Mg2+ , and NADH levels. Advantages of the simultaneous measurement of additional parameters in a single respirometric chamber:

  1. Quality control of preparations by respirometric performance.
  2. Objective exclusion criteria for protocol related problems, e.g. overtitration of uncouplers, side effects of TPP+ or fluorophores.
  3. Elimination of artifacts of normalization for a mitochondrial marker when combining two methods in a single chamber.
  4. Additional information is acquired for a limited amount of sample.
  5. Oxygen dependence of parameters can be studied.

Here we introduce the O2k-Fluorescence LED2-Module, describe one selected stage in its development, and show its application for the simultaneous measurement of respiration and H2O2 production of mouse brain mitochondria.]] โ€ข Keywords: has publicationkeywords::Oxygraph-2k, has publicationkeywords::High-resolution respirometry, has publicationkeywords::Spectrofluorometry, has publicationkeywords::MitoCom

โ€ข O2k-Network Lab: Was published by MiPNetLab::AT_Innsbruck_OROBOROS


Labels:





HRR: Instrument and method::Oxygraph-2k, Instrument and method::Spectrofluorimetry, Instrument and method::MiPNet-Publication