Difference between revisions of "Open chamber"
From Bioblast
Line 3: | Line 3: | ||
|abbr=O | |abbr=O | ||
|description=The term "open O2k-Chamber" refers to a situation in which the liquid phase is allowed to equilibrate with a gas phase, but the stopper is partially inserted using the [[Stopper-Spacer]]. | |description=The term "open O2k-Chamber" refers to a situation in which the liquid phase is allowed to equilibrate with a gas phase, but the stopper is partially inserted using the [[Stopper-Spacer]]. | ||
|info= | |info=[[System]] | ||
}} | }} | ||
== Application in [[HRR]] == | |||
:::: The liquid phase is defined as the system, which is then an [[open system]] with exchange of oxygen with the gas phase, finally resulting in a stable oxygen signal with a [[oxygen flux |slope over time]] of zero. Insert the stopper fully, siphon off any liquid from the receptacle of the stopper, and remove the stopper to a position defined by [[Stopper-Spacer]] to include an optimum volume of the gas phase | :::: The liquid phase is defined as the experimental [[system]], which is then an [[open system]] with exchange of oxygen with the gas phase, finally resulting in a stable oxygen signal with a [[oxygen flux |slope over time]] of zero. Insert the stopper fully, siphon off any liquid from the receptacle of the stopper, and remove the stopper to a position defined by the [[Stopper-Spacer]] to include an optimum volume of the gas phase above the stirred liquid phase. | ||
:::: | ::::» ''Compare'': [[Closed chamber]] | ||
{{Template:Keywords: Oxygen signal}} | {{Template:Keywords: Oxygen signal}} | ||
{{Template:Oroboros QM}} [[Gnaiger Erich]] 2020-09-07 |
Revision as of 11:11, 7 September 2020
Open chamber |
MitoPedia O2k and high-resolution respirometry:
O2k-Open Support
Description
The term "open O2k-Chamber" refers to a situation in which the liquid phase is allowed to equilibrate with a gas phase, but the stopper is partially inserted using the Stopper-Spacer.
Abbreviation: O
Reference: System
Application in HRR
- The liquid phase is defined as the experimental system, which is then an open system with exchange of oxygen with the gas phase, finally resulting in a stable oxygen signal with a slope over time of zero. Insert the stopper fully, siphon off any liquid from the receptacle of the stopper, and remove the stopper to a position defined by the Stopper-Spacer to include an optimum volume of the gas phase above the stirred liquid phase.
- » Compare: Closed chamber
- Bioblast links: Oxygen signal - >>>>>>> - Click on [Expand] or [Collapse] - >>>>>>>
- Specific
- O2k-Procedures
- MiPNet O2k-Procedures
- General
- » Oxygen, dioxygen, O2
- » Oxygen calibration - DatLab
- » Oxygen solubility
- » Oxygen solubility factor
- » Oxygen pressure
- » Concentration
- » Activity
- » Pressure - Pascal
- » Barometric pressure
- » High-resolution respirometry
- » OroboPOS
- » Polarographic oxygen sensor
- » MitoFit Quality Control System
- » Sensitivity
- General
- Other keyword lists
Oroboros quality management from the O2k to NextGen-O2k
Gnaiger Erich 2020-09-07