Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "Oxygen flux - instrumental background"

From Bioblast
Line 3: Line 3:
|description='''Instrumental background oxygen flux (''J''ยฐ<sub>O2</sub>)''', in a respirometer is due to oxygen consumption by the [[POS]], and oxygen diffusion into or out of the aqueous medium in the [[O2k-chamber]].ย  It is measured in the range of experimental oxygen levels by a standardized [[instrumental background test]], and is a property of the instrumental system.ย  Instrumental background correction eliminates errors by systemic flux compensation, automatically performed by [[DatLab 4.3|DatLab]]. See also [[Chemical background correction of oxygen flux]].
|description='''Instrumental background oxygen flux (''J''ยฐ<sub>O2</sub>)''', in a respirometer is due to oxygen consumption by the [[POS]], and oxygen diffusion into or out of the aqueous medium in the [[O2k-chamber]].ย  It is measured in the range of experimental oxygen levels by a standardized [[instrumental background test]], and is a property of the instrumental system.ย  Instrumental background correction eliminates errors by systemic flux compensation, automatically performed by [[DatLab 4.3|DatLab]]. See also [[Chemical background correction of oxygen flux]].
|info=[[MiPNet14.06]]; [[Gnaiger_2008_POS]]; [[Gnaiger_2001_RespPhysiol]]
|info=[[MiPNet14.06]]; [[Gnaiger_2008_POS]]; [[Gnaiger_2001_RespPhysiol]]
|type=Respiration
}}
{{MitoPedia methods
|mitopedia method=Respirometry
|type=Respiration
|type=Respiration
}}
}}
{{MitoPedia topics|type=Respiration
{{MitoPedia topics|type=Respiration
}}
}}

Revision as of 17:21, 15 November 2011


high-resolution terminology - matching measurements at high-resolution


Oxygen flux - instrumental background

Description

Instrumental background oxygen flux (JยฐO2), in a respirometer is due to oxygen consumption by the POS, and oxygen diffusion into or out of the aqueous medium in the O2k-chamber. It is measured in the range of experimental oxygen levels by a standardized instrumental background test, and is a property of the instrumental system. Instrumental background correction eliminates errors by systemic flux compensation, automatically performed by DatLab. See also Chemical background correction of oxygen flux.

Abbreviation: JยฐO2

Reference: MiPNet14.06; Gnaiger_2008_POS; Gnaiger_2001_RespPhysiol


MitoPedia methods: Respirometry