Revision as of 08:12, 19 October 2010 by Gnaiger Erich (talk | contribs) (Created page with " == Can ''P/E'' be higher than 1.0? == OXPHOS capacity can be less than or equal to ETS capacity, but it cannot be higher. Any result giving ''P/E''>1.0 is due to an exp...")
Can P/E be higher than 1.0?
OXPHOS capacity can be less than or equal to ETS capacity, but it cannot be higher. Any result giving P/E>1.0 is due to an experimental artefact. Such an artefact may be obtained due to application of an inhibitory uncoupler concentration, or inhibition of ETS by inhibitors of a component of the phosphorylation system.