Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Search results

From Bioblast
Results 1 โ€“ 21 of 72
Advanced search

Search in namespaces:

ย ย 
ย ย 
ย ย 
ย ย 
ย ย 
ย ย 
ย ย 
ย ย 
ย ย 
ย ย 
ย ย 
ย ย 
ย ย 
  • ...mitochondrial elementary marker, ''mtE'') for normalization of respiratory flux. == Normalization of respiratory flux for CS as a mitochondrial marker ==
    2 KB (222 words) - 16:06, 19 January 2021
  • ...d on internal normalization for rate in a reference state, are independent of externally measured markers and, therefore, are statistically robust. {{#ask:[[Additional label::Normalization of rate]]
    2 KB (260 words) - 23:06, 10 November 2020
  • ...tEU). The [[motive unit]] [MU] of chemical flow or flux is the advancement of reaction [mol] in the chemical format. ...) for the '''Chamber''' volume. Normalization yields a specific quantity ''flux'' from the [[extensive quantity]] ''flow''. From [[Gnaiger 2019 MitoFit Pre
    1 KB (189 words) - 23:30, 25 January 2021
  • ...<sub>O2max</sub>, is less mass-dependent across a large range of body mass of different mammalian species (Weibel and Hoppeler 2005). ...) for the '''Chamber''' volume. Normalization yields a specific quantity ''flux'' from the [[extensive quantity]] ''flow''. From [[Gnaiger 2019 MitoFit Pre
    2 KB (237 words) - 12:16, 16 October 2022
  • ...any form of '''flow''', ''I'' is the [[advancement]] of a process per unit of time, expressed in a specific motive unit [MUโˆ™s<sup>-1</sup>], ''e.g.'', ...e '''Chamber''' volume. Normalization yields the [[specific quantity]] ''[[flux]]'' from the [[extensive quantity]] ''flow''. From [[Gnaiger 2019 MitoFit P
    2 KB (236 words) - 12:49, 23 May 2020
  • ...in a common reference state, to obtain theoretical lower and upper limits of 0.0 and 1.0 (0 % and 100 %). ...n of subsamples obtained from a homogenous mt-preparation or determination of a common [[mitochondrial marker]].
    3 KB (427 words) - 10:40, 24 October 2023
  • ...ed system. The magnitude of these quantities depends on the extent or size of the system ([[Cohen 2008 IUPAC Green Book |Cohen et al 2008]]). ...'''Sample''' (flow per object, mass-specific flux, or cell-volume-specific flux); or (2) for the '''Chamber''' volume. Flow per object and flow per system
    1 KB (143 words) - 12:17, 16 October 2022
  • ...per mg protein or wet mass). These are different forms of [[normalization of rate]]. ...Bureau International des Poids et Mesures (2019) The International System of Units (SI) 9th ed. https://doi.org/10.26124/mitofit:200004.v2, [[Gnaiger 20
    2 KB (276 words) - 10:25, 8 February 2024
  • Version 04: New Section '''6. Normalization of respiratory flux for CS activity''' |keywords=Normalization of rate
    2 KB (204 words) - 15:56, 1 February 2021
  • ...up>-1</sup>ยทx<sup>-1</sup>]. These are different forms of [[normalization of rate]].
    4 KB (658 words) - 01:14, 31 December 2020
  • ...lux, i.e. flux ''E'' in the ET-state, such that the lower and upper limits of the ''CCR'' are defined as 0.0 and 1.0. Then there are two mitochondrial '' |info=[[Flux control ratio]], [[Gnaiger 2020 BEC MitoPathways]]
    2 KB (223 words) - 18:57, 7 February 2021
  • ...r un-inhibited) flux; ''Y<sub>X</sub>'' is the [[background state]] at low flux, upon which ''X'' acts. ...y of ''X'' upon background ''Y<sub>X</sub>'' is expressed as the change of flux from ''Y<sub>X</sub>'' to ''Z<sub>X</sub>'' normalized for the reference st
    8 KB (1,272 words) - 18:27, 1 January 2021
  • ...ab to [[Mark statistics - DatLab|Mark statistics]] (F2), select which type of marks you want to export ("All marks in plot" or "DL-Protocol marks", with == DatLab-Analysis templates for O2k-analysis of respiratory flux - strategy ==
    4 KB (574 words) - 11:36, 25 March 2022
  • ...can be chosen to be displayed as Flux per volume or as normalized specific flux/flow, the background correction can be switched on or off, and the channel ...2k chamber B, in each case the first row is for the signal, the second for Flux/Slope.
    5 KB (769 words) - 15:28, 11 April 2018
  • ...E consortium, following a primary peer-reviewed publication of the concept of stoichiometric potential differences. ...l oxygen consumption, ROX, State 2, State 3, State 4, normalization, flow, flux
    3 KB (369 words) - 12:48, 23 May 2020
  • ...e.g. medians) are displayed for these time sections of the source plot and of all selected plots. ...asurements in a high oxygen regime or using samples with a low respiratory flux or flow.
    6 KB (916 words) - 20:54, 11 June 2023
  • :::: To benefit optimally from the tutored training sessions of the O2k-Virtual Support, please make yourself familiar with '''Materials fo '''Pathway control and coupling control of mitochondrial respiration:'''
    5 KB (754 words) - 12:50, 7 November 2023
  • ...ol ratio]]s. ยป [[Mitochondrial marker#Mitochondrial markers and expression of mitochondrial respiration| '''MiPNet article''']] = Mitochondrial markers and expression of mitochondrial respiration =
    4 KB (536 words) - 13:43, 26 February 2021
  • ...me ''V'' of 0.5 mL. The current DatLab version is included in the delivery of this revolutionary module. ...amilton syringe. Accurate kinetic titrations, however, require application of the TIP2k, with accurately placed needles extending slightly into the mixed
    3 KB (426 words) - 10:05, 14 September 2023
  • :::'''other''' for none of the ones listed above ...le code''' Enter information about your sample by entering any combination of digits and numbers to chamber A. Chamber B will be set accordingly but can
    7 KB (1,153 words) - 13:36, 23 April 2024

View (previous 20 | next 20) (20 | 50 | 100 | 250 | 500)