Mitochondrial membrane potential

Description

The mitochondrial membrane potential, mtMP, is the electric part of the protonmotive force, Ξ”pmt.

Ξ”Οˆmt = Ξ”pmt - Δ¡H+ / F

mtMP or Ξ”Οˆmt is the potential difference across the inner mitochondrial (mt) membrane, expressed in the electric unit of volt [V]. Electric force of the mitochondrial membrane potential is the electric energy change per β€˜motive’ electron or per electron moved across the transmembrane potential difference, with the number of β€˜motive’ electrons expressed in the unit coulomb [C].

The chemical part of the protonmotive force, Β΅H+ / F stems from the difference of pH across the mt-membrane. It contains a factor that bridges the gap between the electric force [J/C] and the chemical force [J/mol]. This factor is the Faraday constant, F, for conversion between electric force expressed in joules per coulomb or Volt [V=J/C] and chemical force with the unit joules per mole or Jol [Jol=J/mol],

F = 96.4853 kJol/V = 96,485.3 C/mol

Abbreviation: mtMP, Ξ”Οˆmt

Reference: Mitchell 1961 Nature, Gnaiger 2014 Preface MiP2014


MitoPedia concepts: Respiratory state, Recommended 


MitoPedia methods: Respirometry, Fluorometry 


MitoPedia topics: EAGLE 

Communicated by Gnaiger E 2012-10-05, edited 2016-02-06.

Template NextGen-O2k.jpg


MitoPedia O2k and high-resolution respirometry: O2k-Open Support 



Different methods for measurements of mt-membrane potential

Mt-membrane potential can either be measured with the O2k-Fluo LED2-Module by using the fluorophores TMRM or Safranin or with the O2k-TPP+ ISE-Module electrode by using the ion reporter TPP+. All mentioned ion reporters inhibit respiration, which makes it essential to test the optimum concentration before starting your experimenal series.
Β» MiPNet15.03 O2k-MultiSensor-ISE
Β» MiPNet17.05 O2k-Fluo LED2-Module
Cookies help us deliver our services. By using our services, you agree to our use of cookies.